United Technologies TruVision SVR Guía de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
TruVision SVR System User Guide 15
DCOM Configuration
DCOM Configuration
The DCOM settings must be the same on all computers connected to the TruVision SVR. Be sure to
close all security management system applications that may be connected to the recorder.
1. In Windows, from the Start menu select Run
2. Type dcomcnfg and click [OK].
3. Access the Distributed COM Configuration Properties by navigating to Component Services >
Computers > My Computer.
4. Right-click on My Computer and select Properties.
5. On the Default Properties tab, make sure it is configured as follows:
Select the Enable Distributed COM on this computer check box.
Clear the Enable COM Internet Services on this computer check box.
Default Impersonation Level should be set to “Impersonate.”
Clear the Provide additional security for reference tracking check box.
6. On the Default Protocols tab, use the buttons to order the list in the exact order shown below:
Connection-oriented TCP/IP
Datagram UDP/IP
Tunneling TCP/IP
Connection-oriented SPX
7. Click [OK].
8. If changes were made, restart the recorder.
9. Verify that the object exporter error does not appear. If the error still occurs, repeat this
procedure, but in step 6, remove the Tunneling TCP/IP protocol from the list of default protocols.